24 Steet StreetFOOTSCRAY · NETWORK
CABLING SCHEDULE ⋅ BUILDING A
Building A — ground floor
The owner’s dwelling at the front, and the studio in the rear half of the garage. Everything lands in the passage cabinet at the back of this floor.
24 STEET ST
FOOTSCRAY
P-03
The alleyway run: passage cabinet → the gate at the street boundary, underground down the south alleyway. ~28–35 m per cable.
50 mm conduit ⋅ draw string left in ⋅ armoured door loop at the gate leaf ⋅ must go in before the alleyway is paved
ITEM
POINTS
places to cable to
CABLES
to pull
LABEL
TERMINATES AT
Data outlet — owner’s dwelling
Bed 1 (master)Living — TV wall ⋅ Dining ⋅ Kitchen appliance ⋅ Garage (front half — door motor, EV, bench)
5
6
Cat6A ⋅ 2 at the TV, 1 elsewhere
A-G-001…6
Patch panel → switch
Data outlet — the studio
Living / TV ⋅ bed area. The rear half of the garage becomes a separate dwelling.
2
3
Cat6A ⋅ 2 at the TV
A-G-007…9
Patch panel → switch
Intercom screen — the studio
UniFi Intercom Viewer. Answers the alleyway gate — the studio is one of its three entries.
1
1
Cat6A
A-G-VIEW
Patch panel → switch (PoE)
Wi‑Fi access point
UniFi U7 Pro ×2 — ceiling of the Living (clear of the skylights, not over the cooktop) and the studio
2
2
Cat6A ⋅ 1 each
A-AP-01, 02
Patch panel → switch (PoE)
Camera — outside
Front corner ⋅ west elevation ⋅ garage front ⋅ alleyway ⋅ rear courtyard.
The alleyway and courtyard cameras mount on the first‑floor overhang — pull those two upstairs.
5
5
Cat6A ⋅ 1 each
A-CAM-01…05
Patch panel → switch (PoE)
Camera — inside the garage
Aimed at the roller door.
1
1
Cat6A
A-CAM-06
Patch panel → switch (PoE)
Gate intercom — the alleyway
UniFi Intercom — touchscreen with a directory of three: upstairs ⋅ granny flat ⋅ studio. Camera and keypad built in.
The ground‑floor dwelling is not on it — it has its own doorbell on the front door.
1
1
Cat6A
A-GATE-RDR
Patch panel → hub reader port
Front door reader
UniFi G6 Pro Entry on D01 — doorbell, camera and PIN keypad in one. This is the ground dwelling’s doorbell.
1
1
Cat6A
A-D01-RDR
Patch panel → hub reader port
Keypad readers — four more doors
D02 garage front corner ⋅ D04 the studio’s front door ⋅ D05 into the passage (the upstairs dwelling’s front door)ID‑01 passage into the kitchen
ID‑01 is an internal door, so it has no D‑number — sheet A22 is the external window and door schedule. This tag is ours.
4
4
Cat6A ⋅ 1 each
A-DR-RDR-02…05
Patch panel → hub reader ports
Exit sensor (REX)
One per controlled door — so leaving doesn’t read as a break‑in.
6
6
2-core ⋅ 1 each
A-DR-REX-01…06
Terminal strip → hub
Door position sensor
Magnetic reed contact — tells the system open or shut. Six controlled doors, plus D06 (the 3370 living slider — contact only, no reader)
7
7
2-core ⋅ 1 each
A-DR-DPS-01…07
Terminal strip → hub
Locks — four strikes, two magnets
Strikes on D01, D02, D05, ID‑01. Magnetic locks on the gate and D04 — a slider and a gate have no swinging latch, so a strike cannot work.
6
6
2-core power ⋅ 1 each
A-DR-LCK-01…06
Terminal strip → hub lock output
22
points to cable to
43
cables to pull
24
of those land on the patch panel
19
land on the terminal strip instead
Equipment to install on the ground floor
What actually gets mounted — owner’s dwelling and studio.
ITEM
SUGGESTED PRODUCT
QTY
WHERE IT GOES
Wall plates + keystones
Cat6A keystones
8 / 10
Owner’s dwelling ×5, studio ×2, intercom screen ×1
Wi‑Fi access point
UniFi U7 Pro
2
Living ceiling ⋅ studio ceiling
Intercom screen
UniFi Intercom Viewer
1
Studio — answers the alleyway gate
Camera
UniFi G6 Turret
6
5 outside ⋅ 1 inside the garage at the roller door
Gate intercom
UniFi Intercom
1
Alleyway gate — three-entry directory
Front door reader
UniFi G6 Pro Entry
1
Outside D01 — doubles as the doorbell
Keypad reader
UniFi UA‑G2
4
D02 ⋅ D04 ⋅ D05 ⋅ ID‑01
Exit sensor
PIR request‑to‑exit
6
Inside each controlled door
Door position sensor
Magnetic reed contact
7
Six controlled doors + D06, the living slider
Electric strike
Cabler‑supplied, matched to the door
4
D01 ⋅ D02 ⋅ D05 ⋅ ID‑01
Magnetic lock
Fail‑safe by design — opens on power loss
2
Gate and D04 — a strike cannot hold a slider or a gate
Access hub
UniFi EAH‑8 — hub 1 of 2
1
Passage cabinet — drives all six perimeter doors
Where every cable goes
One strand per cable. They run in parallel, and each one lands in one of two places — never straight onto a device.
Bed 1 — master Living — TV wall Dining Kitchen — appliance Garage — front half Studio — living / TV Studio — bed area Studio — intercom screen Access point — Living Access point — studio Camera — front corner Camera — west elevation Camera — garage front Camera — alleyway Camera — rear courtyard Camera — inside garage Gate — intercom D01 — front door D02 — garage corner D04 — studio front door D05 — into the passage ID-01 — passage to kitchen D06 — living slider PATCH PANEL then patched to the switch 24 cables land here TERMINAL STRIP then jumpered to the hub 19 cables land here Two destinations — never straight onto a device Data & Wi‑Fi — 12 Cameras — 6 Door — 19 Lock power — 6
← PREVIOUSHow it all connectsNEXT →Upper floor