Building C — the server room
The head‑end for the whole site. The NBN connection arrives here, and so does everything from Building B and the fibre from Building A. This is the one room that, if it goes down, takes the other two buildings with it.
24 STEET ST
FOOTSCRAY
This is a brick outbuilding with a barbecue in it. Heat, grease aerosol, humidity and insects are all real here in a way they are not in a house. The gear must sit in a sealed, lockable, ventilated cabinet inside the enclosed store portion — partitioned from the cooking area, on its own circuit.
This room holds the recorder with all the footage on it. Treat it as the most security‑sensitive space on the site
What goes in the cabinet
Top to bottom, as it should be built.
15U CABINET — THE STORE ROOM Cable management 1U 15 Patch panel — 24 port 1U 17 of 24 used — C’s 7 plus Building B’s 10 14 Cable management 1U 13 USW‑Pro‑48‑PoE 1U Carries C’s devices and all of Building B’s ⋅ 4 × SFP+ 12 Cable management 1U 11 UniFi Dream Machine Pro Max 1U Gateway + controller + recorder ⋅ 2 × 8 TB inside, mirrored 10 FOBOT — fibre enclosure 1U F‑01 out to Building A lands here 9 Shelf — NTD + EAH‑8 hub 2U NBN box ⋅ the hub drives C’s door and B’s 8 7 DIN rail — terminal strip, ~16 way 1U Six low‑voltage runs land here — two doors 6 Shelf — hub battery 1U Keeps Building B’s front door working through a cut here 5 UPS 2U Covers Building B as well — B has none of its own 4 3 Spare 2U Measure the store room before ordering any of this. 2 1 The whole outbuilding is about 17.7 m². This has to fit inside the enclosed store portion — measure before ordering.
15U
cabinet height
23
cables arriving — C’s 10 plus B’s 13
17 / 6
on the patch panel / terminal strip
17/48
switch ports used
Everything that lands in this room
One strand per cable, grouped by where it lands. Four destinations, four media — they are parallel paths, not a chain.
C Kitchen outlet C Store outlet C Wi‑Fi access point C Camera — position 7 C Camera — server‑room door C Entry reader B Bedroom 1 B Bedroom 2 B Living — TV wall B Living — second point B Wi‑Fi access point B Cameras ×2 B Intercom screen B Entry reader C Exit sensor C Door position sensor C Electric strike B Exit sensor B Door position sensor B Electric strike Fibre F‑01 from Building A NBN lead‑in from the street PATCH PANEL 17 Cat6A land here then patched to the switch TERMINAL STRIP 6 low‑voltage runs then jumpered to the hub FOBOT 1 fibre, out to Building A NTD → GATEWAY the carrier handoff Data & Wi‑Fi — 13 Cameras — 4 Door — 6 Lock power — 2 Fibre — 1 NBN — 1
NEXT SHEET
The full parts list is on its own sheet — “What goes in the server room”. Twenty‑three line items across active network, door access, termination, power and the room itself.
← PREVIOUSCabling scheduleNEXT →Server room equipment list